| 1 | EVSE installation test adapter | Connects installation-test instruments to an AC charging point; simulates vehicle connection and charging states; checks control-pilot behavior and selected protective functions. | Pilot-state response, voltage presence, PE continuity checks when supported, and RCD-test access through a compatible installation tester. | IEC 61851-1; IEC 62196; IEC 60364-7-722; IEC 61557 series for applicable installation tests. | Commissioning and field inspection of AC EVSE installations. | Confirm connector type, regional wiring arrangement, supported pilot states, and compatibility with the separate installation tester. |
| 2 | AC EVSE functional analyzer | Checks AC charging-point operation, control-pilot signaling, proximity detection, contactor switching, and configurable charging states. | Pilot duty cycle or state, proximity state, output voltage, phase behavior, and basic start/stop response, depending on the instrument. | IEC 61851-1; IEC 62196; SAE J1772 for applicable North American interfaces; relevant national EVSE requirements. | AC charger troubleshooting, production checks, and service verification. | Check whether it supports the target AC interface and whether readings are diagnostic or suitable for documented verification. |
| 3 | EVSE protocol and communication tester | Tests digital communication between an EV and EVSE, including supported message sequences, session control, and communication fault handling. | Protocol state transitions, message exchange, session establishment, error responses, and communication logs. | ISO 15118; DIN SPEC 70121 where implemented; IEC 61851-24 for applicable DC communication; regional protocol requirements. | EVSE development, interoperability testing, and communication fault analysis. | Verify supported protocol versions, plug-and-charge functions if required, test-case coverage, and software-update policy. |
| 4 | DC fast-charger analyzer | Evaluates DC EVSE output behavior and charging-session functions using a compatible vehicle simulator, load, or test system. | DC output voltage and current, charging-state response, isolation-monitoring behavior where supported, and session faults. | IEC 61851-23; IEC 61851-24; IEC 62196; regional DC charging standards such as GB/T 18487.1 and GB/T 20234, as applicable. | DC charger commissioning, engineering validation, and service diagnostics. | Check maximum voltage/current range, connector and protocol coverage, safety interlocks, and whether a separate load is needed. |
| 5 | Programmable EV simulator | Emulates vehicle-side signaling and, in advanced systems, charging communication so an EVSE can be tested without a road vehicle. | Connection-state changes, pilot response, charging requests, supported communication sequences, and fault scenarios. | IEC 61851 series; ISO 15118; DIN SPEC 70121 where supported; applicable regional interface standards. | R&D, design verification, and repeatable EVSE functional testing. | Confirm whether the simulator covers AC, DC, or both; check protocol versions, scenario control, and logging/export options. |
| 6 | Programmable DC load or battery emulator | Provides a controlled load or simulated battery response for testing DC charger output and selected charging profiles. | DC voltage, current, power, load steps, response time, and programmed operating profiles within the system’s ratings. | IEC 61851-23 and applicable regional DC charging requirements; IEC 61010-1 for relevant measurement/control equipment safety. | Laboratory performance tests and controlled DC output verification. | Match voltage, current, power, duty cycle, cooling, energy handling, and protection ratings to the charger under test. |
| 7 | RCD and residual-current tester | Tests residual-current protection and trip behavior in an EV charging installation, using test methods appropriate to the installed protective device. | Trip time and, where supported, trip current or response to specified residual-current waveforms. | IEC 61557-6; IEC 60364-7-722; IEC 61851-1 provisions for applicable EV supply equipment protection. | Electrical installation inspection and protective-device verification. | Check supported RCD types and waveforms, test current settings, and compatibility with the charger’s specified protection scheme. |
| 8 | Insulation resistance and continuity tester | Checks insulation and protective-conductor continuity on suitable installation circuits or isolated equipment, following safe test procedures. | Insulation resistance and low-resistance continuity; test voltage and measurement range depend on the instrument. | IEC 61557-2 for insulation resistance; IEC 61557-4 for resistance of earth connections and equipotential bonding; IEC 60364-7-722. | Installation acceptance, maintenance, and safety checks. | Use only on circuits and equipment for which the test method is appropriate; isolate sensitive electronics and follow local procedures. |
| 9 | Power-quality analyzer | Monitors supply and load behavior during charging, helping identify power-quality issues and characterize charger operation. | Voltage, current, frequency, power, power factor, harmonics, and event trends, subject to instrument capability. | IEC 61000-4-30 for power-quality measurement methods; IEC 61000-4-7 for harmonic measurement; IEC 61010-1 for relevant equipment safety. | Site diagnosis, load studies, and engineering evaluation during charging. | Check measurement class, current-sensor range, phase configuration, data logging, and calibration status. |
| 10 | Reference power and energy meter | Measures electrical energy and power during controlled EVSE tests; can support comparison against the charger’s displayed or reported values. | Energy, active power, voltage, current, and power factor, with accuracy determined by the meter and test setup. | IEC 62052 and IEC 62053 where applicable to the meter type; IEC 61010-1 for relevant measurement equipment safety. | Performance verification, energy-meter comparison, and laboratory testing. | Review accuracy class, calibration traceability, measurement range, connection method, and whether the meter is intended for billing or test use. |